tipcontrol – view lighting with digital control

Our engineers, who are responsible for further developments have made the lighting

arrangement more efficient, comfortable and, above all, safer.

The rifle scope you have purchased possesses a new power-saving micro-controller that

combines the maximum of operating comfort at a large dimming range with a high

degree of safety against unintended on and off switching. When not in use, it switches

off automatically. Undesired use of the battery can thus almost always be avoided. And

for the final touch of reliability, a spare battery chamber is also provided.

Inserting the battery

First open the battery chamber cap (1). Then place a lithium battery

CR2032(2)(provided) into the battery chamber with the plus side facing upwards and

press it in the middle to click it into place. The writing on the button cell must be legible.

Also practice the correct removal of the battery.

Removing the battery

First screw the battery chamber cap (1) off. Now the button cell (2) can be removed in

that the cell is strongly pressed with the thumb or the forefinger at one of the points

where the black edge is slotted (3), thus in the direction of the lens or the ocular, until

the other side of the battery disengages and projects.

Operation

Both switching on and off occurs by means of a double click on the button with the

DOCTER logo (4), thus a strong quick short double- click.

Brightness setting

The change of brightness of the calibrating plate is carried out by means of a longer

press of approximately one second on the control button (4).

The brightness increases as long as the button is pressed. When released the

brightness adjustment remains.

Subsequent pressing reverses the direction of the change of brightness.

The view blinks when the maximum or minimum intensity has been reached. The button

(4) must then be released to achieve a reverse of the change again.

Dual-Memory function

On switching on again, a secure perceptible light point intensity that is adjusted with the

memory function is immediately set and can be recognised under all lighting conditions.

The last set brightness is recalled by means of a three times click when switching on.

Automatic switch off

The lighting unit possesses a time-controlled off switching. The lighting switches off if no

button operation has taken place for 180 minutes.