Installation

Air Exhaust Ventilation

FIRE AND EXPLOSION HAZARD
Be sure to read and follow the warnings and
precautions regarding HAZARDOUS
FLUIDS,
and FIRE OR EXPLOSION
HAZARD
on pages 2 and 3, before operat-
ing this pump.

Be sure the system is properly ventilated for your type
of installation. You must vent the exhaust to a safe
place, away from people, animals, food handling areas,
and all sources of ignition when pumping flammable or
hazardous fluids.

Diaphragm failure will cause the fluid being pumped to
exhaust with the air. Place an appropriate container at
the end of the air exhaust line to catch the fluid. See
Fig. 6.

WARNING

The air exhaust port is 3/4 npt(f). Do not restrict the air
exhaust port. Excessive exhaust restriction can cause erratic
pump operation.

To provide a remote exhaust:

1.

Remove the muffler (P) from the pump air exhaust
port.

2.

Install a grounded air exhaust hose (T) and connect the
muffler (P) to the other end of the hose. The minimum
size for the air exhaust hose is 3/4 in. (19 mm) ID. If a
hose longer than 15 ft (4.57 m) is required, use a larger
diameter hose. Avoid sharp bends or kinks in the hose.

3.

Place a container (U) at the end of the air exhaust line
to catch fluid in case a diaphragm ruptures. See Fig. 6.

Figure 6

KEY

A

Air supply line

B

Bleed-type master air valve
(required for pump)

C

Air regulator

D

Air line quick disconnect

E

Master air valve (for accessories)

F

Air line filter

P

Muffler

T

Grounded air exhaust hose

U

Container for remote air exhaust

F

B

E

C

A

D

VENTING EXHAUST AIR

P

T

U

02650