Performance chart – Graymills DDP 1' Aluminum Pump User Manual

Page 25

Advertising
background image

25

Performance Chart

Test Conditions:

Pump tested in water with inlet submerged.

0

20

40

60

80

100

120

0

5

10

15

20

25

30

35

40

(0.7, 7)

Fluid Pressure Curves

A at 120 psi (0.7 MPa, 7 bar) air pressure

B at 100 psi (0.7 MPa, 7 bar) air pressure

C at 70 psi (0.48 MPa, 4.8 bar) air pressure

D at 40 psi (0.28 MPa, 2.8 bar) air pressure

A

B

D

To find Fluid Outlet Pressure (psi/MPa/bar)
at a specific fluid flow (gpm/lpm) and operating
air pressure (psi/MPa/bar):

1. Locate fluid flow rate along bottom of chart.

2. Follow vertical line up to intersection with

selected fluid outlet pressure curve.

3. Follow left to scale to read fluid outlet

pressure.

FLUID OUTLET PRESSURE

––

psi (MPa, bar)

(0.55, 5.5)

(0.41, 4.1)

(0.28, 2.8)

(0.14, 1.4)

C

(0.84, 8.4)

FLUID FLOW--gpm (lpm)

(38)

(133)

(152)

(76)

(114)

(95)

(57)

(19)

0

10

20

30

40

50

60

0

5

10

15

20

25

30

35

40

FLUID FLOW--gpm (lpm)

AIR CONSUMPTION

––

scfm (cubic meters/min)

To find Pump Air Consumption (scfm or m

#/min)

at a specific fluid flow (gpm/lpm) and air pressure
(psi/MPa/bar):

1. Locate fluid flow rate along bottom of chart.

2. Read vertical line up to intersection with

selected air consumption curve.

3. Follow left to scale to read air consumption.

(38)

(133)

(1.68)

(152)

(76)

(114)

(1.40)

(1.12)

(0.84)

(0.56)

Air Consumption Curves

A at 120 psi (0.7 MPa, 7 bar) air pressure

B

at 100 psi (0.7 MPa, 7 bar) air pressure

C at 70 psi (0.48 MPa, 4.8 bar) air pressure

D at 40 psi (0.28 MPa, 2.8 bar) air pressure

B

C

A

D

(0.28)

(95)

(57)

(19)

Advertising