24 HOUR HEATER TIMERS

This is the screen where the operator can set the internal clock of the machine as well as enable/disable the ability to determine when
the heaters will be used on the Liftkleen. Heater functionality is optional and is only available on aqueous units.

2

1

3

Number Description

c

SET CLOCK – Pressing this button opens the clock setting window (See Below)

d

SUN, MON, TUE, WED, THU, FRI, SAT – Press these to edit and enable/disable the 24/7 timer settings for those
individual days (See Below)

e

HOME – Returns to HOME screen

Setting Machine Clock

1. Press SET CLOCK button

c

.

2. Time-change screen will appear (right).
3. Press + and – buttons until proper date/time has been achieved. Please note that the

hours used in the control program are in a 24-hour format.
Example: 1:30 pm = 13:30 hours (12 hours + 1:30 hours)

4. Press ENT when finished to return to the 24/7 Heater-Timer Setup Screen

Individual Day Settings

1. Press button for day of the week desired.
2. Setting screen for individual day will appear (right).
3. Press BACK when finished to return to the 24/7 Heater-Timer Setup Screen.

Enable/Disable

To enable or disable timed heat for that day, press the large button on the right until it
reads DISABLED or ENABLED.

Setting ON/OFF Time

1. Press the hours button for ON or OFF.
2. Enter the hour of day you wish the heat to be enabled/disabled on the number keypad (right).

Please note that the hours used in the control program are in a 24-hour format. Press ENTER
when finished.

3. Press the minutes button for ON or OFF.
4. Enter the minute of the hour you wish the heat to be enabled/disabled on the number keypad

(right). Press ENTER when finished.