VP-4x8 - Connecting the VP-4x8

11

Hardware flow control is not required for this unit. In the rare case where a

controller requires hardware flow control, short pin 1 to 7 and 8, and pin 4 to 6 on

the controller side.

Method B (

Figure 6

)—Connect the RS-232 9-pin D-sub port on the unit via a

straight (flat) cable to the null-modem adapter, and connect the null-modem

adapter to the RS-232 9-pin D-sub port on the PC. The straight cable usually

contains all nine wires for a full connection of the D-sub connector. Because the

null-modem adapter (which already includes the flow control jumpering described

in Method A above) only requires pins 2, 3 and 5 to be connected, you are free to

decide whether to connect only these 3 pins or all 9 pins.

Figure 6: Straight Cable RS-232 Connection with a Null Modem Adapter

5.3

Connecting the RS-485 Port to a PC or Controller

You can operate the VP-4x8 via the RS-485 port from a distance of up to 1200m

(3900ft) using any device equipped with an RS-485 port (for example, a PC). For

successful communication, you must set the RS-485 machine number and bus

termination.

To connect a device with a RS-485 port to the VP-4x8:

Connect the A (+) pin on the RS-485 port of the PC to the A (+) pin on the

RS-485 port on the rear panel of the VP-4x8

Connect the B (–) pin on the RS-485 port of the PC to the B (–) pin on the

RS-485 port on the rear panel of the VP-4x8

Connect the G pin on the RS-485 port of the PC to the G pin on the RS-485

port on the rear panel of the VP-4x8



1

2

6

3

7

4

8

5

9

to PC

Null-Modem

Adapter