VP-4x8 - Connecting the VP-4x8

5.6

Cascading Machines

You can cascade up to 16 VP-4x8 units with control from a PC or serial controller

(see

Figure 10

).

To cascade up to 16 individual VP-4x8 units via RS-485, do the following:

1. Connect the VGA/UXGA sources and acceptors, as

Section 5.1

describes.

2. Connect the RS-232 (or RS-485) port on the first VP-4x8 unit to the PC

using the null-modem adapter provided with the machine (recommended),

as

Section 5.2

describes.

3. Connect the RS-485 terminal block port on the first unit to the RS-485 port

on the second VP-4x8 unit and so on, connecting all the RS-485 ports.

4. Set the DIP-switches, as shown in

Section 5.5

:

Set the first VP-4x8 unit as Machine # 1 and the following 15 VP-4x8

units as Machine # 2 to Machine # 16, according to

Section 5.5.2

Set DIP 8 ON on the first and last VP-4x8 units (terminating the

RS-485 line at 120

Ω). Set DIP 8 OFF on the other VP-4x8 units

Set DIP 5, DIP 6 and DIP 7 OFF on all VP-4x8 units