Flash Memory Upgrade

46

12 Flash Memory Upgrade

The main part of the unit firmware is located in FLASH

1

Download the up-to-date file from the Internet or obtain it from your dealer.

The following example shows how to install a file named (for example)

“162-15.hex” to the FLASH memory

memory, which

lets you upgrade to the latest Kramer firmware version in minutes!

2

The current unit software version shows in the STATUS display as

.

Figure 14

illustrates in section

10.1

.

12.1 Connecting the PC to the RS-232 Port

Before installing the latest Kramer firmware version on a unit, connect:

The COM port on your PC to the RS-232 IN port on the unit

When simultaneously upgrading the firmware on several units:

Connect the COM port on your PC to the RS-232 IN port on the

first unit

Connect the RS-232 OUT port on the first unit to the RS-232 IN

port on the second unit or another 16x16 unit

Connect all 16x16 units that you want to upgrade, in this way,

linking them in a daisy chain connection

Set DIP 7 according to whether or not a null-modem connection is

being used

3

12.2 Upgrading the Firmware

1. Install and run the K-Sender program on your PC.
2. Open the K-Sender program.

The File COM Port Sender window opens.

3. Choose the appropriate COM port.

Be sure that “9600 Baud rate” is chosen.

Click the File button.

4. Locate the file “162-15.hex” and click the Open button.

The filename appears in the lower part of the window (in bold script).

1 Electrically programmable and erasable
2 The number “15” in the file name indicates the version number “1.5”. Be sure you receive the latest version, and that it is a
“.hex” file
3 Refer to section

8.1

for full details