Connecting the VS-828 Video / Audio Matrix Switcher

13

6.3 Controlling via RS-232 and RS-485

You can control up to eight single

VS-828 units with control from a PC via

RS-232 (see section 6.2) and RS-485 as illustrated in Figure 6.
To control via RS-232 and RS-485, do as follows:

1. Connect the video sources and acceptors, the appropriate audio sources

and acceptors, and the power cord to each

VS-828 unit.

2. On each

VS-828 unit, set the Self Address dipswitches, as required

1

(see

Table 4).

3. Connect the RS-232 port on the first unit to the PC

2

.

4. Interconnect the RS-485 ports on all the

VS-828 units: from the RS-485

port on the first

VS-828 unit, to the RS-485 port on the second VS-828

unit, and so on – up to the RS-485 port on the last unit.

5. Terminate the RS-485 line as described in section 6.1.2.

Self Address = 1 (Master)

Self Address = 3

Figure 6: RS-232 and RS-485 Operation

1 The first unit (the master) will be set to Self Address = 1
2 As in section 6.2