Communication protocol, 21 table 7: protocol instruction codes – Kramer Electronics VS-626 User Manual

Page 24

Advertising
background image

Communication Protocol

21

Table 7: Protocol Instruction Codes

Note: All values in the table are decimal, unless otherwise stated.

INSTRUCTION

DEFINITION FOR SPECIFIC INSTRUCTION

#

DESCRIPTION

INPUT

OUTPUT

NOTE

0

RESET MACHINE

0

0

1

1

SWITCH VIDEO

Set equal to video input to be

switched

Set equal to video output to be switched

(0=to all the outputs)

2

2

SWITCH AUDIO

Set equal to audio input to be

switched

Set equal to audio output to be switched

(0=to all the outputs)

2

3

STORE STATUS

Set as SETUP # 1-6 (1-8) for

the VS-626 (VS-828)

- To store parameters

- to delete setup

2,7

4

RECALL STATUS

Set as SETUP # 1-6 (1-8) for

the VS-626 (VS-828)

Don’t care

2,7

5

REQUEST STATUS OF A

VIDEO OUTPUT

Set as SETUP # 1-6 (1-8) for

the VS-626 (VS-828)

Equal to output number whose status is

read

3,7

6

REQUEST STATUS OF

AN AUDIO OUTPUT

Set as SETUP # 1-6 (1-8) for

the VS-626 (VS-828)

Equal to output number whose status is

read

3,7

7

VIS SETTING

Don’t care

- for immediate switching

- for VIS switching

2

8

BREAKAWAY SETTING

Don’t care

- for audio-follow-video

- for breakaway

2

9

NOT USED

10

REQUEST VIS SETTING

Set as SETUP # 1-6 (1-8) for

the VS-626 (VS-828)

Don’t care

3,7

11

REQUEST BREAKAWAY

SETTING

Set as SETUP # 1-6 (1-8) for

the VS-626 (VS-828)

Don’t care

3,7

12 to

14

NOT USED

15

REQUEST WHETHER

SETUP IS DEFINED

Set as SETUP # 1-6 (1-8) for

the VS-626 (VS-828)

Don’t care

4

16

ERROR/BUSY

Don’t care

Don’t care

5

17

RESERVED

6

18

RESET MACHINE

0

0

1

19

STORE STATUS

Set as SETUP # 1-6 (1-8) for

the VS-626 (VS-828)

0-to store parameters

1-to delete setup

2,7,9

20

RECALL STATUS

Set as SETUP # 1-6 (1-8) for

the VS-626 (VS-828)

Don’t care

2,7,10

21 to

56

NOT USED

57

SET AUTO-SAVE

for auto save

0 – no save

Don’t care

8,2

58 to

60

RESERVED

61

IDENTIFY MACHINE

1or 2 – machine name

3 or 4 – version

Don’t care

11

NOTES ON THE ABOVE TABLE:

NOTE 1 - When the master switcher is reset, (e.g. when it is turned on), the reset code is sent to the PC. If this code is sent to the

switchers, it will reset according to the present power-down settings.

NOTE 2 - These are bi-directional definitions. That is, if the switcher receives the code, it performs the instruction, and if the instruction

is performed (due to a keystroke on the front panel), then these codes are sent. For example:

0000 0001

1000 0101

1000 1000

0011

was sent from the PC, then the switcher (machine # 3) will switch input 5 to output 8. If the user switched input # 1 to output # 7 via the

front panel keypad, then the switcher will send:

0100 0001

1000 0001

1000 0111

1000 0011

to the PC.