Defining the vs-66fw 6 port firewire switcher – Kramer Electronics VS-66FW User Manual

Page 11

Advertising
background image

Defining the VS-66FW 6 Port FireWire Switcher

7

Table 1: Front Panel VS-66FW 6 Port FireWire Switcher Features

# Feature

Function

1 IR Receiver

The red LED is illuminated when receiving signals from the Infra-red remote

control transmitter

2

Power

Switch

Illuminated switch for turning the unit ON or OFF

3

ALL

Button

Pressing

ALL

followed by an BRANCH button, connects that BRANCH to all

LEAF

devices

1

4

OFF

Button

An

OFF

-

LEAF

combination disconnects that

LEAF

from the BRANCH devices;

an

OFF

-

ALL

combination disconnects all the

LEAF

devices

5

LEAF

Buttons

Select 1 - 6 to connect between a BRANCH device and a

LEAF

device

6

BRANCH

Buttons

Select 1 - 6 to connect between a

LEAF

device and a BRANCH device

7

STO

(STORE) Button Pressing STO followed by a

LEAF

button stores the current setting

2

8

RCL

(

RECALL

) Button

Pressing the

RCL

button and the corresponding

LEAF

button recalls a setup

from the non-volatile memory. The stored status blinks. Pressing a different

LEAF

button lets you view

3

another setup. After making your choice, pressing

the

RCL

button again implements the new status

9

LOCK

Button

Toggles engaging/disengaging the front panel switches. The button is lit

when the switches are locked (disengaged)

10

TAKE

Button

Pressing

TAKE

toggles the mode between the

CONFIRM

mode

4

and the

AT

ONCE

mode (user confirmation per action is unnecessary)

11

LEAF

Labels identify a cross point between each LEAF

to which the BRANCH

displayed below it is connected

12

BRANCH

7-segment

Display

5

shows the selected BRANCH switched to the LEAF

(under

the corresponding LEAF

label)

13 PORT STATUS LEDs Lights when data from an external device is detected on that port

Table 2: Rear Panel VS-66FW 6 Port FireWire Switcher Features

# Feature

Function

1 PORT

Connects to the FireWire device(s) (from 1 to 6)

2

RS-232 IN

DB 9F Port

Connects to the PC or the RS-232 Remote Controller

3

REMOTE

Terminal Block

Connector

Connects to the Remote contact-closure switches

4

RS-485

Terminal Block Port

Pin G is for Ground connection; Pins + and – are for RS-485

5

RS-232 OUT

DB 9F Port

Connects to the RS-232 IN DB 9F port of the next unit in a

daisy-chain

6 SETUP Dipswitches

Dipswitches for setup of the unit (1, 2, 3 and 4 are for setting the

Machine #; 8 is for RS-485 Termination)

7

FLASH

Program Button

Push in

6

for “Program” to upgrade to the latest Kramer firmware

(see section 7), or release for Normal (the factory default)

7

8 Power Connector with Fuse AC connector enabling power supply to the unit

1 For example, press ALL and then BRANCH button # 2 to connect BRANCH # 2 to all the LEAF devices
2 For example, press STO and then the LEAF button # 3 to store in Setup # 3
3 Only view, nothing is implemented at this stage
4 When in Confirm mode, the TAKE button illuminates
5 Also displays the firmware version number. Refer to section 6.1
6 Using a screwdriver if required
7 Note that the FLASH PROG “Reset” button is located on the underside of the unit. Push in for “Reset”, or release for
Normal (see section 7)

Advertising