10

5.3 Controlling via RS-485

You can control a

VS-66FW unit via any RS-485 remote controller or a PC

(equipped with an RS-485 interface).
To connect an RS-485 remote controller to a

VS-66FW:

1. Connect the RS-485 port on the RS-485 remote controller to the RS-485

ports on the

VS-66FW unit, as follows:

Connect the “A” (+) PIN on the RS-485 remote controller to the “+” (A)

PIN on the RS-485 port of the

VS-66FW unit

Connect the “B” (-) PIN on the RS-485 remote controller to the “B” (-)

PIN on the RS-485 port of the

VS-66FW unit

If shielded twisted pair cable is used, the shield may be connected to the

“G” (Ground) PIN on one of the units (for example, on the RS-485 remote

controller)

2. Set the SETUP dipswitches on the

VS-66FW unit as follows:

Set the first

VS-66FW unit to MACHINE # 1

1

Set the second

VS-66FW unit to MACHINE # 2

1

and set DIP 8 to ON,

terminating the RS-485 line

2

5.4 Setting the Dipswitches

Figure 6 illustrates the factory default dipswitches:

Figure 6: Dipswitch Settings

Table 3: Dipswitch Settings

Function

DIPS

Description

Machine #

1, 2, 3, 4 Determines the position of a unit in the sequence (see section 5.4.1)

Reserved

5

OFF

Reserved

6

OFF

Reserved

7

OFF

RS-485 Termination 8

ON for RS-485 Line Termination with 120 ;

OFF for no RS-485 Line Termination

1 See Table 3
2 The RS-485 line must also be terminated at the remote controller. Refer to the remote controller’s user manual for details of
how to terminate the RS-485 line on the remote controller