Connecting the VS-88HCB
17
6.5 Setting the VS-88HCB Dipswitches
This section describes the machine set-up and dipswitch selection.
Figure 11 illustrates the factory default dipswitches and Table 3 describes
them.
OFF
ON
Figure 11: VS-88HCB Dipswitches
Table 3: Dipswitch Settings
DIPS
Function
Description
1, 2, 3
Self Address
Determines the position of the machine in the input expansion configuration
(in the factory default, these DIPs are set to ON)
4
RS-485 TERM
ON for RS-485 Line Termination (factory default)
OFF for no RS-485 Line Termination
5
Reply
ON enables reply from switcher to PC (factory default)
OFF disables reply from switcher to PC
6, 7
RESERVED
Set to ON (factory default)
8
RS-232 \ RS-485
ON enables RS-232 communication between switcher and PC (factory
default)
OFF disables reply from switcher to PC