Kramer Electronics FC-10ETH User Manual
Page 21

18
FC-10ETH - Controlling Machines via the Ethernet using the FC-10ETH
Unit (B) is configured to the Active mode.
6. Connect units (A) and (B) to your network or Ethernet router, as illustrated in
7. Connect up to two machines, that is, the RS-232:
COM 1 port of the FC-10ETH (A) to the RS-232 port of your machine 1
(for example, a Kramer machine) via a null modem adapter
COM 2 port of the FC-10ETH (A) to the RS-232 port of your machine 2
(for example, a Kramer machine) via a null modem adapter
(alternatively, you can connect the RS-485 port of unit (A) to the
RS-485 port of your Kramer machine).
To connect the RS-485 port, c
onnect PIN A to the “A” (+) PIN and PIN B to the
“B” (–) PIN
8. Connect up to two serial controllers to unit (B):
Connect the RS-485 terminal block of the serial controller (1) to the
RS-485 terminal block port on the FC-10ETH (B)
Alternatively, you can connect an RS-232 output terminal block of the serial
controller to the RS-232 COM 2 port of the FC-10ETH
Connect the RS-232 port of the serial controller (2) to the RS-232 COM
1 port on the FC-10ETH (B)
9. Connect the power on each of the devices as follows:
The Kramer machines
FC-10ETH (A)
Connect the 12V DC power adapter to the power socket and connect the adapter
to the mains electricity
FC-10ETH (B)
Connect the 12V DC power adapter to the power socket and connect the adapter
to the mains electricity
The serial controllers
A connection is established after the user sends the first command
from the serial controller to the serial controlled device.
i
i