7

Setting Scaler Functions

Default Settings

The SP-14 comes with default setting that should give good results on most content but you do need
to decide on some parameters for your application. As you get used to the unit you can be more
adventurous


Input resolution and frame rate


The input resolution and frame rate is recognised automatically and displayed on top line of the
status menu screen

IN: 1920x1080i @50.00 Hz 3G-SDI 1

OUT:1920x1080i @59.94 Hz Free Run Mode
Unlocked Keypad Preset 1
3G-SDI 1 C-YPbPr HDMI Test Pat



In this example the input is 1920x1080P at 50Hz from the 3G-SDI input 1


Set Processor Output Resolution and Frame Rate

Set the processor output resolution and frame rate you require in the Output Settings menu
Using the up and down arrow keys move Output Settings to the top of the window and press select

[Output Settings ]↑
Audio

Closed Captioning

Information



Using the up and down arrow keys move Output Format to the top of the window and press select

[Output Format 1080i50]↑
Arc Mode Side Panels/Ltrbox 25%
Arc Custom N/A
Process Mode Full Processing ↓


Press select, use the left and right arrow keys to choose the output format, press select

Output Format > 1080i50<
Arc Mode

Arc Custom

Process Mode