Instructions- 3" (80mm) pp Flex in b Vent

1. Remove existing B Vent termination cap
2. Carefully feed flex down through B Vent so
approx 2' of flex extends beyond the bottom
of the B Vent (Flex puller or rope aid optional)
3. Cut to length the top of Flex pipe and
insert flex through B Vent Adapter- Upper
4. Install PP Flex Gasket and Flex Female
Adapter
onto Flex pipe per instructions
detailed above
5. Lower B Vent Adapter- Upper to the top
of the B Vent and secure with screws (x3)
supplied
6. Install C Support Bracket as shown in Fig.14
and lower Flex Female Adapter into B Vent
Adapter- Upper
7. Attach Termination Top to Termination Cap
(clicks when engaged), insert 3" Rigid Pipe
into Termination Cap, and attach Termination
Insert
into Termination Cap (clicks). Then
connect Termination Insert to Termination
Transition
(click).
8. Line up inner pipe connections and push
termination assembly down onto B Vent
Adapter- Upper
and secure with screws (x3)
provided
9. Cut Flex to length 3" below the bottom of
the B Vent
10. Install Flex Gasket and Flex Male Adapter
on Flex
11. Install B Vent Adapter- Lower. (Flex Male
Adapter
should protrude beyond per Fig.13)
12. Secure B Vent Adapter- Lower to B Vent
with hardware provided

Figure 13

B Vent PiPe

flex Male

aDaPteR

B Vent

aDaPteR-

loweR

MountinG

haRDwaRe

teRMination caP

flex Male aDaPteR

3" (80MM) flex Gasket

B Vent aDaPteR- loweR

teRMination tRansition

B Vent aDaPteR- uPPeR

B Vent PiPe

teRMination inseRt

3" (80MM) RiGiD PiPe

c suPPoRt BRacket

MountinG haRDwaRe

flex feMale aDaPteR

3" (80MM) flex

3" (80MM) flex Gasket

Figure 15- (3" Flex / B Vent)

teRMination toP

Figure 14

B Vent

PiPe

B Vent

aDaPteR-

uPPeR

flex

feMale

aDaPteR

c suPPoRt

BRacket