Application / listing, Permits, Minimum clearance to combustibles – DuraVent PolyPro Flex User Manual

Page 4

Advertising
background image

4

applICatIon / lIStIng

For specific information on application,
equivalent length of fittings, listings, etc.,
please reference M&G Duravent's installation
instructions for rigid pipe (Document L273).

M&G Duravent's PolyPro vent pipe should not
be installed in areas where the temperature
could exceed 230 F / 110 C.

pErmItS

Check with your local Building Official, Fire
Official, or other authority having jurisdiction
regarding permits, restrictions, and
installation inspections in your area.

mInImum ClEaranCE to

CombuStIblES

Refer to Table A for minimum clearances
to combustible materials. Use the values
shown in this table unless the appliance
manufacturer specifies otherwise. If there
is a conflict between the two, the greater
clearance shall apply. It is prohibited to place
any type of insulation around the venting
system within these clearances.

Installation applications and

terminations shown in these

instructions must be approved by

the manufacturer of the appliance to

which it is applied. use only listed m&g

DuraVent terminations with polypro

Venting.

CautIon

Important

the vent system must terminate in

accordance with local code requirements

and appropriate national Codes:

In the uS: nFpa 54 / anSI Z223.1

national Fuel gas Code or the

International Fuel gas Code.

In Canada: Can/Cga-b149.1 natural

gas Installation Code or Can/Cga-149.2

propane Installation Code.

table a

minimum Clearance to Combustibles table

VEnt orIEntatIon

ClEaranCE

Horizontal

Single Wall: 0" for flue temperatures up to 194*F (90*C).

1/4" (6mm) for flue temperatures up to 230*F (110*C).

Flex: N/A- NOT ALLOWED

Vertical

Single Wall: 0"

Flex: 0" (Must be enclosed)

gEnEral InStallatIon notES

Reference the Installation Instructions
provided with M&G Duravent's rigid pipe
(L273) for general instructions. pp Flex must

be enclosed, and used in conjunction with

rigid pp pipe to connect to an appliance.

When used to conduct flue gases, PP flex
must not be installed at an angle greater
than 45 degrees from vertical. This will
ensure proper condensate flow back
towards the appliance outlet.

PP Flex may be used to bring
combustion air into the appliance. In
these instances, pipe can be unenclosed
and oriented in a vertical or horizontal
position.

PP flex must be treated carefully to
prevent damage when being installed
during low temperatures (<41°F, < 5 °C).
In colder weather, pre-warm flex prior
to installation. When relining, it may be
easier to insert flex from the bottom up