Step 1

Plug fan into 120 Volt outlet
on the front of the Mercury 2.

Step 2

Set your preferred fan setting
on the Mercury 2.

OptiOnal SettingS

inStRUCtiOnS – Rev. a

“Fire-Up” Feature

The customer can easily enable or disable the “Fire-Up” feature by following
the instructions below. The “Fire-Up” feature will active your fan at 100%
for 2 seconds and then reduce the speed to match your preferred setting
whenever your fan is activated for the first time or you experience a power
outage. This improves the start up of your fan and extends the life of your
fan. It is recommended that you enable the ‘Fire-Up’ feature if you set your
Mercury 2 at slow speeds. The default setting from the factory enables the
“Fire-Up” feature.

Note: This unit has been set to perform in the

“Fire-Up” position from the factory.

100%

OFF

10%

50%

100%

OFF

10%

50%

100%

OFF

10%

50%

Step 3

Plug the Mercury 2 into single phase 120 Volt wall outlet
and fan should be activated at your preferred setting.

installation is now complete.

The “Fire-up” feature can be activated by the customer by:
• Unplugging the Mercury 2 and setting the knob to “100%”.

(Diagram 2)

• Then plug the Mercury 2 into your 120 volt outlet, turn to 10%

and then turn to 100% within three (3) seconds. (Diagram 3)

• To verify the setting, plug your fan into the Mercury 2, then

unplug the Mercury 2 and plug back in to see (or hear) the effect
of the “Fire-Up” feature in action