General data

316L corresponds to 1.4404 or 1.4435, 316Ti corresponds to 1.4571

Materials

-

Housing

plastic PBT, Alu die-casting, 316L

-

Inspection window in housing cover for
indicating and adjustment module

Polycarbonate (UL-746-C listed)

-

Ground terminal

316Ti/316L

Weight

0.35 kg (0.772 lbs)

Ambient conditions

Ambient temperature

-15 … +70 °C (+5 … +158 °F)

Storage and transport temperature

-40 … +80 °C (-40 … +176 °F)

Electromechanical data

Cable gland

1 x cable gland M20 x 1.5 (cable: ø 5 … 9 mm), 1 x
blind stopper M20 x 1.5 or 1 x closing cap ½ NPT,
1 x blind stopper ½ NPT

Spring-loaded terminals for wire cross-sec-
tion up to

2.5 mm² (AWG 14)

Indicating and adjustment module

Voltage supply and data transmission

through the sensor via gold-coated sliding contacts
(I²C-Bus) in the external indicating and adjustment
unit

Indication

LC display in dot matrix

Adjustment elements

4 keys

Protection rating

-

unassembled

IP

20

-

mounted in the external indicating and
adjustment unit without cover

IP

40

Materials

-

Housing

ABS

-

Inspection window

Polyester foil

Adjustment circuit

Connection to

IPT-1* sensors

Data transmission

digital (I²C-Bus)

Configuration connection cable

4-wire, screened

Cable length

max. 25 m