3.11 Operating conditions model O-10 (5)

Ingress protection (per IEC 60529)

For ingress protections see "Electrical connections model O-10 (5)"

The stated ingress protection only applies when plugged in using mating connectors that have the

appropriate ingress protection.

Vibration resistance (per IEC 60068-2-6)

20 g (20 ... 2,000 Hz, 120 min)

Shock resistance (per IEC 60068-2-27)

40 g (6 ms), mechanical shock

Service life

10 million load cycles

Free fall test

Resistant to an impact onto concrete from 1 m

Temperatures

Medium: -40 ... +100 °C

Ambient: -25 ... +80 °C

Storage: -25 ... +80 °C

Other temperature ranges on request

3. Specifications