Specifications – WIKA O-10 User Manual

Page 19

Advertising
background image

19

WIKA operating instructions pressure transmitter model O-10

GB

11613017.04 05/2013 GB/D/F/E

3. Specifications

3.14 Electrical connections model O-10 (T)

Available connections

Electrical connection

Ingress

protection

Wire cross-

section

Cable

diameter

Cable

lengths

Angular connector DIN 175301-803 A IP 65

-

-

-

Angular connector DIN 175301-803 C IP 65

-

-

-

Circular connector M12 x 1 (4-pin)

IP 67

-

-

-

Metri-Pack series 150

1)

IP 67

-

-

-

Cable outlet, unshielded

2)

IP 67

0.14 mm

2

3.4 mm

2 m , 5 m

Cable outlet, shielded

IP 67

0.14 mm

2

4.3 mm

2 m , 5 m

1) for model O-10 (T) only possible from measuring range 0 ... 60 bar

2) up to a maximum of 80 °C permitted

The stated ingress protection (per IEC 60529) only applies when plugged in using mating connectors

that have the appropriate ingress protection.

Short-circuit resistance

S+ vs. 0V

Reverse polarity protection

UB vs. 0V

Overvoltage protection

DC 36 V

Insulation voltage

DC 750 V

Advertising