6.3.2 Programming the display

1. Connect instrument in accordance with connection diagram

2. Switch on the current loop supply (current between 4 ... 20 mA)

An initialisation and segment test is carried out. Then DIH10 and

subsequently the firmware version number (e.g. F1.24) is displayed.

Following this, the display switches into operating mode.

3. Press the program button P, the program number P 0 will be

displayed

4. By pressing P and the button or P and the button

simultaneously, change the program number

5. Under the selected program number, switch to the stored value with

the P button

6. By pressing P briefly, the required digit can be selected;

the selected digit is changed using or

7. The entry is saved by pressing the P button for approx. 2 seconds;

the value has been saved once the display shows horizontal bars

8. If no button is pressed, after approx. 7 seconds the instrument

returns to operating mode

Additional functions in normal operation to retrieve the recorded

Min/Max values

Using the button, the recorded value of the Max memory is

shown in the display for some seconds

Using the button, the recorded value of the Min memory is

shown in the display for some seconds

By simultaneously pressing the and the buttons, the Min and

Max values are deleted

CAUTION!

If the measuring range setting is changed, to maintain the

measuring accuracy, the display must be recalibrated.