Specifications, Ce compliance – Young Temp Tracker Model 46203 User Manual

Page 4

Advertising
background image

Page 3

46203-90

MINIMUM / MAXIMUM

The Temp Tracker stores minimum and maximum values for both

displays. To view minimum and maximum values, depress the

SET/ RESET key momentarily. Each time the key is depressed, the

display switches modes; first to

MIN then MAX then back to Cur-

rent values. To reset all values, press and hold the SET / RESET

key until the unit beeps.

The Temp Tracker may be set to automatically cycle through

MIN,

MAX and Current values. This feature is selected during SETUP.

Minimum and maximum values reset if power is interrupted.

REMOTE DISPLAYS

The Temp Tracker may be used as a remote or slave display by

selecting InP SEr during SETUP. Remote displays are connected

to the Main display using the RS-485 terminals. Connect like

terminals as shown in the wiring diagram. Remote displays show

exactly the same information as the Main display. MIN / MAX and

SETUP functions are controlled at the Main unit only. Brightness is

adjusted at each display independently.

VOLTAGE OUTPUTS

The Temp Tracker offers calibrated voltage outputs for both chan-

nels. This feature allows the use of recorders and other devices.

Full scale voltage for each channel is 5.00 VDC.

ERROR MESSAGES

The Temp Tracker will detect and indicate certain errors. Once cor-

rected, the error indication disappears.

Display

Error

LEFT RIGHT

- - -

- - -

4-20 mA signal from sensor is not present or is

outside acceptable range.

SEr

Err

Unit is set up to receive serial input signal, but

no data is being received. Verify that main unit

is

operating. Check cable connections.

WARRANTY

The Temp Tracker is warranted to be free of defects in materials and

workmanship for a period of 12 months from the date of purchase.

This warranty is limited to repair or replacement of defective unit.

SPECIFICATIONS

• Size

144 x 144 x 36 mm (5.65 x 5.65 x 1.4 in)

• Panel Cutout

138 x 138 mm (5.43 x 5.43 in)

• Sensor Type

YOUNG Model 41382LC2 RH / T

YOUNG Model 41342LC T only

• Input Signal

T

4-20mA = -50 to +50°C

RH

4-20mA = 0 to 100%

• Serial I/O

RS-485, binary data block,

16 blocks per second

• Accuracy

Temperature ±0.1 °C (0.2°F)

Relative Humidity ±0.1 %

Dew Point ±0.5 °C (0.9 °F)

(These accuracies are for the Temp Tracker

only and are independent of sensor accuracy.)

• Voltage Output 0.00 to 5.00 VDC

Scale

Temperature and Dew Point:

-50 to 50 °C, -50 to 150 °F

Relative Humidity: 0 to 100%

• Alarm relays

Normally open, non-latching,

5A resistive, 2A inductive @ 24 VAC or

30 VDC

• Power

requirement

12 to 30 VDC, 4.5 watts

• Weight

0.75 lbs (0.34 kg)

• Accessories

Model 06280 Rack Mounting Panel

CE COMPLIANCE

This product has been tested and shown to comply with European CE

requirements for the EMC Directive (see Declaration of Conformity

below). Shielded cable must be used.

Declaration of Conformity

R. M. Young Company

2801 Aero Park Drive

Traverse City, MI 49686 USA

Model 46203 TEMP TRACKER

The undersigned hereby declares on behalf of R. M.

Young Company that the above-referenced product, to

which this declaration relates, is in conformity with the

provisions of:

Council Directive 2004/108/EC (December 15, 2004)

on Electromagnetic Compatibility

David Poinsett

R&D Manager