Technical parameters, Ramp scales – RADWAG WPT/2K 300/600H Overhead Track Scales User Manual
Page 73

- 73 -
22. TECHNICAL PARAMETERS
22.1. Ramp scales
Scale type:
WPT/4N
400H1
WPT/4N
400H2
WPT/4N
800H2
WPT/4N
800H3
Max capacity
400kg
800kg
Min capacity
4kg
10kg
Readability 200g
500g
Verification division
200g
500g
Range of tare
- 400kg
- 800kg
Operation temperature
-10°C to +40°C
Ingress protection rating
IP 68 platform, IP 66/67 indicator
Power supply
230V AC, 50Hz / 11V AC
and internal gell cell SLA 6V accumulator
Supplied from batteries
Average operation when supplied from batteries 45h
Display
LCD with backlight
Platform size
840 x 860mm
1,1 x 1,2m
1,1 x 1,2m
1,2 x 1,5m
Weight of scale with indicator
105kg
180kg
Dimensions of weight [mm] 1710x1160x76
2050x1420x76 2350x1520x76
Scale type:
WPT/4N
1500H2
WPT/4N
1500H3
WPT/4N
1500H4
Max capacity
1500kg
Min capacity
10kg
Readability 500g
Verification division
500g
Range of tare
-1500kg
Operation temperature
-10°C to +40°C
Ingress protection rating
IP 68 platform, IP 66/67 indicator
Power supply
230V AC, 50Hz / 11V AC
and internal gell cell SLA 6V accumulator
Supplied from batteries
Average operation when supplied from batteries 45h
Display
LCD with backlight
Platform size
1,1 x 1,2m
1,2 x 1,5m
1,5 x 1,5m
Weight of scale with indicator
190kg
230kg
270kg
Dimensions of weight [mm] 2150x1420x77
2450x1520x77 2450x1820x77