2 power down mic bias, 3 power down adc charge pump, 4 power down adc x – Cirrus Logic CS42L56 User Manual
Page 58: 5 power down, 4 power control 2 (address 04h), 1 headphone power control, Ed in, Headphone power con, P 59, Cs42l56

58
DS851F2
CS42L56
6.3.2
Power Down MIC Bias
Configures the power state of the microphone bias output.
6.3.3
Power Down ADC Charge Pump
Configures the power state of the ADC charge pump. For optimal ADC performance and power consump-
tion, set to 1b when VA > 2.1 V and set to 0b when VA < 2.1 V.
6.3.4
Power Down ADC x
Configures the power state of ADC channel x.
6.3.5
Power Down
Configures the power state of the entire CODEC.
6.4
Power Control 2 (Address 04h)
6.4.1
Headphone Power Control
Configures how the HPDETECT pin, controls the power for the headphone amplifier.
PDN_BIAS
MIC Bias Status
0 Powered
Up
1
Powered Down
PDN_CHRG
ADC Charge Pump Status
0 Powered
Up
1
Powered Down
PDN_ADCx
ADC Status
0
Powered Up
1
Powered Down
PDN
CODEC Status
0 Powered
Up
1
Powered Down
7
6
5
4
3
2
1
0
PDN_HPB1
PDN_HPB0
PDN_HPA1
PDN_HPA0
PDN_LINB1
PDN_LINB0
PDN_LINA1
PDN_LINA0
PDN_HPx[1:0]
Headphone Status
00
Headphone channel is ON when the HPDETECT pin, is LO.
Headphone channel is OFF when the HPDETECT pin, is HI.
01
Headphone channel is ON when the HPDETECT pin, is HI.
Headphone channel is OFF when the HPDETECT pin, is LO.
10
Headphone channel is always ON.
11
Headphone channel is always OFF.