Figure 3. i2c control port timing, Switching characteristics - i, Figure 3. i – Cirrus Logic CS4391 User Manual
Page 10: Cs4391, C control port

CS4391
10
DS335PP4
SWITCHING CHARACTERISTICS - I
2
C CONTROL PORT
(T
A
= 25° C; VL = 5.5 to 1.8 Volts; Inputs: logic 0 = AGND, logic 1 = VL, C
L
= 30 pF)
Notes: 23. Data must be held for sufficient time to bridge the 300 ns transition time of SCL.
Parameter
Symbol
Min
Max
Unit
I
2
C
®
Mode
SCL Clock Frequency
f
scl
-
100
KHz
RST Rising Edge to Start
t
irs
500
-
ns
Bus Free Time Between Transmissions
t
buf
4.7
-
µs
Start Condition Hold Time (prior to first clock pulse)
t
hdst
4.0
-
µs
Clock Low time
t
low
4.7
-
µs
Clock High Time
t
high
4.0
-
µs
Setup Time for Repeated Start Condition
t
sust
4.7
-
µs
SDA Hold Time from SCL Falling
(Note 23)
t
hdd
0
-
µs
SDA Setup time to SCL Rising
t
sud
250
-
ns
Rise Time of Both SDA and SCL Lines
t
r
-
1
µs
Fall Time of Both SDA and SCL Lines
t
f
-
300
ns
Setup Time for Stop Condition
t
susp
4.7
-
µs
t
buf
t
hdst
t
hdst
t
lo w
t r
t f
t
hdd
t high
t sud
t sust
t susp
Stop
S tart
S ta rt
Stop
R e p e a te d
S D A
S C L
t
irs
R S T
Figure 3. I
2
C Control Port Timing