Switching characteristics - control port, Figure 2. i2c control port timing, Cs4396 – Cirrus Logic CS4396 User Manual

Page 9

Advertising
background image

CS4396

DS288PP1

9

SWITCHING CHARACTERISTICS - CONTROL PORT

(T

A

= 25 °C; VD = 5.25 V to 3.0 Volts; Inputs: logic 0 = AGND, logic 1 = VD, C

L

= 30 pF)

Notes: 8. Data must be held for sufficient time to bridge the 300 ns transition time of SCL.

Parameter

Symbol

Min

Max

Unit

I

2

C

®

Mode

SCL Clock Frequency

f

scl

-

100

KHz

RST Rising Edge to Start

t

irs

500

-

ns

Bus Free Time Between Transmissions

t

buf

4.7

-

µs

Start Condition Hold Time (prior to first clock pulse)

t

hdst

4.0

-

µs

Clock Low time

t

low

4.7

-

µs

Clock High Time

t

high

4.0

-

µs

Setup Time for Repeated Start Condition

t

sust

4.7

-

µs

SDA Hold Time from SCL Falling

(Note 8)

t

hdd

0

-

µs

SDA Setup time to SCL Rising

t

sud

250

-

ns

Rise Time of Both SDA and SCL Lines

t

r

-

1

µs

Fall Time of Both SDA and SCL Lines

t

f

-

300

ns

Setup Time for Stop Condition

t

susp

4.7

-

µs

t

buf

t

hdst

t

hdst

t

low

t r

t f

t

hdd

t

high

t sud

t sust

t susp

Stop

Start

Start

Stop

Repeated

SDA

SCL

t

irs

RST

Figure 2. I

2

C Control Port Timing

Advertising