Figure 5. control port timing - i·c format, Figure 5.control port timing - i²c format – Cirrus Logic CS5345 User Manual

Page 20

Advertising
background image

20

DS658F4

CS5345

SWITCHING CHARACTERISTICS - CONTROL PORT - I²C FORMAT

Inputs: Logic 0 = DGND = AGND = 0 V, Logic 1 = VLC, C

L

= 30 pF.

19. Data must be held for sufficient time to bridge the transition time, t

fc

, of SCL.

20. Guaranteed by design.

Parameter Symbol

Min

Max

Unit

SCL Clock Frequency

f

scl

-

100

kHz

RESET Rising Edge to Start

t

irs

500

-

ns

Bus Free Time Between Transmissions

t

buf

4.7

-

µs

Start Condition Hold Time (prior to first clock pulse)

t

hdst

4.0

-

µs

Clock Low time

t

low

4.7

-

µs

Clock High Time

t

high

4.0

-

µs

Setup Time for Repeated Start Condition

t

sust

4.7

-

µs

SDA Hold Time from SCL Falling

(Note 19)

t

hdd

0

-

µs

SDA Setup time to SCL Rising

t

sud

250

-

ns

Rise Time of SCL and SDA

(Note 20)

t

rc

, t

rd

-

1

µs

Fall Time SCL and SDA

(Note 20)

t

fc

, t

fd

-

300

ns

Setup Time for Stop Condition

t

susp

4.7

-

µs

Acknowledge Delay from SCL Falling

t

ack

300

1000

ns

t

buf

t

hdst

t

lo w

t

hdd

t

high

t

sud

Stop

S ta rt

S D A

S C L

t

irs

R S T

t

hdst

t

rc

t

fc

t sust

t susp

S ta rt

Stop

R e p e ate d

t

rd

t

fd

t

ack

Figure 5. Control Port Timing - I²C Format

Advertising