An362 – Cirrus Logic AN362 User Manual
Page 4

AN362
4
AN362REV1
3.1Accuracy Results for Active Energy Load Performance
Figure 3. Active Energy Load Performance vs. IEC 62053-22 Class 0,2S Standard
Power Factor
Load Current (A)
Current Dynamic Range (x:1)
Error
PF = 1
80
1
0.04%
8
10
0.04%
0.8
100
0.04%
0.16
500
0.04%
0.08
1000
0.07%
0.04
2000
0.05%
0.03
3333
0.06%
0.02
4000
0.02%
Lagging PF = 0.5
80
1
0.05%
8
10
0.05%
0.8
100
0.04%
0.16
500
0.06%
0.08
1000
0.05%
0.04
2000
0.06%
Leading PF = 0.5
80
1
0.04%
8
10
0.04%
0.8
100
0.05%
0.16
500
0.04%
0.08
1000
0.05%
0.04
2000
0.07%
Table 1. Active Energy Load Performance
-0.6
-0.4
-0.2
0
0.2
0.4
0.6
0.01
0.1
1
10
100
Percent Error (%
)
Load Current (A)
PF = 1
Lagging PF = 0.5
Leading PF = 0.5
Note: CS5480, where U
n
= 240
V, I
b(max)
= 2
(80
A) at 50
Hz
IEC 62053-22 Class 0,2S Spec, Lagging PF = 0.5 or Leading PF = 0.8
IEC 62053-22 Class 0,2S Spec, PF = 1