An362 – Cirrus Logic AN362 User Manual
Page 5

AN362
AN362REV1
5
3.2Accuracy Results for Reactive Energy Load Performance
Figure 4. Reactive Energy Load Performance vs IEC 62053-23 Class 2 Standard
Power Factor
Load Current (A)
Current Dynamic Range (x:1)
Error
sin
= 1
80
1
0.00%
8
10
0.01%
0.8
100
0.01%
0.16
500
-0.02%
0.08
1000
-0.02%
0.04
2000
-0.01%
0.03
3333
0.00%
0.02
4000
-0.03%
Lagging sin
= 0.5
80
1
0.23%
8
10
0.24%
0.8
100
0.17%
0.16
500
0.21%
0.08
1000
0.16%
0.04
2000
0.22%
Leading sin
= 0.5
80
1
-0.20%
8
10
-0.20%
0.8
100
-0.26%
0.16
500
-0.23%
0.08
1000
-0.25%
0.04
2000
-0.24%
Table 2. Reactive Energy Load Performance
-3
-2
-1
0
1
2
3
0.01
0.1
1
10
100
Pe
rc
e
n
t Err
o
r (
%
)
Load Current (A)
sin
ࢥ = 1
Lagging sin
ࢥ = 0.5
Leading sin
ࢥ = 0.5
Note: CS5480, where U
n
= 240
V, I
b(max)
= 2
(80
A) at 50
Hz
IEC 62053-23 Class 2 Spec, sin
ࢥ = 0.5
IEC 62053-23 Class 2 Spec, sin
ࢥ = 1