3 rogowski coil power meter example, Figure 8. rogowski coil power meter, Cdb5480u – Cirrus Logic CDB5480U User Manual
Page 13
Advertising

CDB5480U
DS893DB5
13
1.6.3
Rogowski Coil Power Meter Example
Rogowski coil power meter can be easily connected to the CDB5480U evaluation board. Figure 8 shows
the voltage and current connections for the Rogowski sensor and its associated filter configurations.
Figure 8. Rogowski Coil Power Meter
For more information, see AN365: Using the CS5480/84/90 Energy Measurement IC with Rogowski Coil
Current Sensors.
IIN1-/IIN2-
IIN1+/IIN2+
GND
GND
GND
LINE
CS
5480
CDB5480U
PH
AS
E
NEU
TRA
L
J1/J12
J4
J7/J13
J8/J14
J11
J6
R5
1K
C5/C11
0.033UF
C6/C12
0.033UF
C9
0.027UF
C4
0.027UF
R11/R22
NO POP
R1/R21
100
R2/R22
100
R7 1K
R6 1K
R9/R23
NO POP
R13/R24
NO POP
R8 422K
R12 422K
R14 422K
R15 422K
R49/R52
1K
R50/R53
1K
C34/C1
0.033UF
C35/C2
0.033UF
J44/J51
J46/J52
R51/
R54
0
J45
J53/J56
J54/J55
IIN1+/IIN2+
IIN1-/IIN2-
VIN-
VIN+
Advertising