7 conversion window, 1 single conversion button, 2 continuous conversion button – Cirrus Logic CDB5480U User Manual

Page 27: Figure 21. conversion window, Cdb5480u

Advertising
background image

CDB5480U

DS893DB5

27

2.7

Conversion Window

The Conversion window allows the user to see the results of single and continuous conversions and the
CS5480 status, perform data averaging, and utilize the power-saving modes of the CS5480. The
Conversion window can be accessed from the System menu pull-down, Conversion menu item. The
Conversion window provides the active, apparent, and reactive energy calculations register results for
each channel. In addition, the RMS, power factor, and peak signal amplitudes for each analog-to-digital
converter channel, chip temperature (when temperature measurement function is enabled), AC line
frequency (converted from the Epsilon register), and the values of each status register (Status0, 1, 2) are
also displayed. The Conversion window also provides the total active, apparent, and reactive power
register results.

Figure 21. Conversion Window

2.7.1

Single Conversion Button

Pressing the Single Conversion button will cause a single conversion to be performed. After a single
conversion is complete, the Result column will be updated with the values present in each data register.

2.7.2

Continuous Conversion Button

Pressing this button will cause continuous conversions to be performed until the user presses the Stop
button. After each conversion is complete, the Result column will be updated with the values present in
each data register. The Mean and STD. DEV columns will be updated every N cycle, where N is the

Advertising