ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-179

© 2000, ADC Telecommunications, Inc.

DLP-555

Page 2 of 2

7. After a download is finished, a message appears to indicate whether the download was

successful or unsuccessful.

•

If successful, the MPU will reboot automatically to ensure that the configuration
database takes effect. Stop! You have completed this procedure.

•

If unsuccessful, repeat Steps 3 through 6.

5323-A

SYSTEM MAINTENANCE

1. Force/APS Commands
2. Reset/LED Test Commands
3. Execute ACO (Alarm Cut-Off)
4. Loopback Status/Commands
5. Display Inventory
6. Display Circuit IDs
7. Upload/Download Commands
8. Test Access Unit Commands

Press CONTROL-A For Assistance

Figure 555-1. System Maintenance Menu

9449-A

UPLOAD/DOWNLOAD COMMANDS

1. Execute Configuration Data Upload

2. Execute Configuration Data Download

3. Execute Software Download

Press CONTROL-A For Assistance

Figure 555-2. Upload/Download Commands Menu