ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-184
© 2000, ADC Telecommunications, Inc.

DLP-557

Page 2 of 3

6. Move to the Mon Type Alarms toggle fields. The following selections are possible:

•

Critical

–

Allows notification of all Critical alarms as they occur.

•

Major

–

Allows notification of all Major and Critical alarms as they occur.

•

Minor

–

Allows notification of all Minor, Major, and Critical alarms as they occur.

•

Event

–

Allows notification of all alarms and events as they occur.

Reference:

TAP-101

Alarm Troubleshooting

7. Assign the selections by pressing Enter or Return.

8. Repeat Steps 3 through 7 for each HDSL facility in the chassis.

Note:

Pressing CONTROL-C and confirming with Y removes all threshold values and

alarm level information from the database for the group and slot selected.

Stop! You have completed this procedure.

6147-B

HDSL PERFORMANCE MONITORING CONFIGURATION

Group: 6 Circuit: 1 Circuit ID:

15 MINUTE DAILY
=================== ===================
MONTYPE THRESHOLD ALM LEVEL THRESHOLD ALM LEVEL
======= ========= ========= ========= =========
FCP 5 EVENT 480 EVENT
CVP 6893 EVENT 67579 EVENT
ESP 65 EVENT 648 EVENT
SESP 10 EVENT 100 EVENT
SEFSP 10 EVENT 100 EVENT

CVs PER SES: 165

Press CONTROL-A For Assistance, CONTROL-C To Clear All PM Counts

Figure 557-1. HDSL PM Configuration Screen (Typical)