Ds3 mux alarm levels screen is shown in, Figure 560-1, Default values are shown in – ADC Soneplex Broadband System User Manual

Page 215: Table 560-1

Advertising
background image

ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-192
© 2000, ADC Telecommunications, Inc.

DLP-560

Page 2 of 2

DS3MUX ALARM LEVELS

Equipment Alarms
===========================
BOARD FAIL : MAJOR
COMM FAIL : MAJOR
PROTECT COMM FAIL: MINOR

MUX Facility Alarms
===========================
FORCE TO WORKING : MINOR
FORCE TO PROTECT : MINOR
APS LIMIT : MINOR
DS3 LOS : MAJOR
DS3 LOF : MAJOR
DS3 AIS : MAJOR
DS3 YELLOW : MINOR
DS3 IDLE : MINOR
DS3 LOOPED BACK : MINOR

Press CONTROL-A For Assistance

6682-B

Figure 560-1. DS3 MUX Alarm Levels

Table 560-1. DS3 MUX Alarm Level Defaults

EQUIPMENT ALARMS

ALARM TYPE DEFAULT

CONDITION

ONLINE

OFFLINE

BOARD FAIL

Major

Minor

COMM FAIL

Major

Minor

PROTECT COMM FAIL

Minor

Event

DS3 FACILITY ALARMS

ALARM TYPE DEFAULT

CONDITION

ONLINE

OFFLINE

FORCE TO WORKING

Minor

Event

FORCE TO PROTECT

Minor

Event

APS LIMIT

Minor

Event

DS3 LOS

Major

Minor

DS3 LOF

Major

Minor

DS3 AIS

Major

Minor

DS3 YELLOW

Minor

Event

DS3 IDLE

Minor

Event

DS3 LOOPED BACK

Minor

Event

Advertising