7-5

KIP Solenoid Selection

7

Solenoid Selection

Selecting the Best Solenoid Operator for Your Application

Adapter

Nut

Housing

Stop Orifice

(Normally Open)

Spring Loaded

Top Seal

Coil

Plunger

Spring,

Plunger, Rtn

Bottom Seal

Body

Body Orifice

(Normally Closed)

Shading Ring

(AC Only)

Guide Assembly

1/2" NPT Conduit

FEATURE

KIP Jr. (Series 9)

Series 1

Series 2

Series 3

Series 6

Size - Diameter (inches)

0.80

1

1

1-3/16

1-5/8

Maximum MOPD (psi)

100

800

1000

1000

1200

Vacuum Service

¤

¤

¤

¤

¤

Max. Cv - Body

0.050

0.305

0.305

0.490

0.610

Min. Cv - Body

0.035

0.030

0.030

0.030

0.035

Max. Cv - Stop

0.025

0.125

0.140

0.140

0.270

Min. Cv - Stop

0.015

0.025

0.025

0.025

0.024

Power Rating

.65 watts

6 watts

7 watts

7 watts

10 watts

Lead Wire Gauge

24 AWG

20 AWG/18 AWG

20 AWG/18 AWG

18 AWG

18 AWG

Low Wattage Operators to 1.5 Watt

Available

Available

Available

Available

N/A

1/8" NPTF Ports - Body

¤

¤

¤

¤

¤

1/4" NPTF Ports - Body

¤

¤

3/8" NPTF Ports - Body

4

#10 - 32 UNF Ports - Body

¤

¤

¤

¤

¤

1/8" NPT or 1/4" NPT Male Bottom Port

¤

¤

¤

UL Recognized

¤

¤

¤

¤

CSA Approved

¤

¤

4

¤

Grommet Style Housing

¤

¤

¤

¤

¤

Conduit Style Housing

¤

¤

¤

¤

Spade Terminal Style - (Standard)

1/4"

1/4"

1/4"

Spade Terminal Style - (Options)

3/16"

3/16"

Yoke Style (Open Frame)

¤

¤

Side Metering

¤

¤

Bottom Metering

¤

¤

Extended Flow Capabilities

¤

¤

¤

¤

¤

Operator Mount Manifolds

¤

¤

¤

¤

Valve Mount Manifolds

¤

¤

¤

¤

Diaphragm Isolated Version

¤

¤

¤

¤

Advertising