Vollrath E257 User Manual

Page 11

Advertising
background image

3

2.1 SAFETY PRECAUTIONS
Do not attempt to operate the freezer until the safety
precautions and operating instructions in this manual are
read and completely understood.

Take notice of all warning labels on the freezer (Figures 6
& 7). The labels have been put there to help maintain a safe
working environment. The labels have been designed to
withstand washing and cleaning. All labels must remain
legible for the life of the freezer. Labels should be checked
periodically to be sure they can be recognized as warning
labels.

If danger, warning, or caution labels are needed, indicate
the part number, type of label, location of label, and
quantity required along with your address and advise your
distributor.

2.2 SHIPMENT AND TRANSIT
The freezer has been assembled, operated and
inspected at the factory. Upon arrival at the final destina-
tion, the complete freezer must be checked for any
damage which may have occurred during transit.

With the method of packaging used, the freezer should
arrive in excellent condition. THE CARRIER IS
RESPONSIBLE FOR ALL DAMAGE IN TRANSIT,
WHETHER VISIBLE OR CONCEALED.

Do not pay the freight bill until the freezer has been
checked for damage. Have the carrier note any visible
damage on the freight bill. If concealed damage and/or
shortage is found later, advise the carrier within 10 days
and request inspection. The customer must place claim
for damages and/or shortages in shipment with the carrier.

2.3 FREEZER INSTALLATION
Installation of the freezer involves moving the freezer close
to its permanent location, removing all crating, setting in
place, assembling parts, and cleaning.

A. Uncrate the freezer.

B. The floor model freezers must be placed in a

solid level position. To level the freezer, turn the bottom
part of each leg in or out. Place a level on top of the
hopper, with the cover removed, to check whether or not
the freezer is level (Fig. 5).

SECTION 2

INSTALLATION INSTRUCTIONS

NOTE

Accurate leveling is necessary for correct
drainage of freezer barrel and to insure proper
operation.

C. The counter model freezer must be placed on a solid

level surface. Place the rubber pad furnished under the
freezer to create a seal to that surface. The counter
model freezer is air-cooled and discharges at the top.
AL LOUVERED PANELS MUST have 3" of clearance
on sides of unit, 10" of clearance at the top, and 1"
clearance at rear of unit for proper cooling.

Figure 5

Adjustable Leg

Advertising