D. The floor model freezers are equipped with air-cooled

condensers and require correct ventilation. The front of
the freezer is the air intake and must be unobstructed.
Air discharges out of the rear of the unit. Do not obstruct
the discharge. Allow a 6" (15.2 cm) clearance behind
the unit (Fig. 8).

CAUTION

FAILURE TO PROVIDE ADEQUATE VENTILATION WILL
VOID WARRANTY!

Figure 8

Space and Ventilation Requirements

E. Place the ON-OFF-STIR ONLY toggle switch in the

OFF position. This switch is located on the lower left of
the freezer, under the drip tray and cover.

F. Connect the power cord. The plug is designed for 115

volt/15 amp duty. The unit must be connected to a
properly grounded receptacle. The electrical cord
furnished as part of the freezer has a three prong
grounding type plug (Fig.9). The use of an extension
cord is not recommended. If one must be used, use one
with a wire, size 12 gauge or heavier, with a ground. Do
not use an adaptor to avoid grounding equipment.

CAUTION

DO NOT ALTER OR DEFORM PLUG IN ANY WAY!

Figure 10

Installing Drip Tray and Cover

Figure 9

Electrical Plug

G. Install the drip tray support, drip tray, drip tray grid,

cover and miscellaneous parts on the freezer. (Fig. 10)