Vollrath 219-02 User Manual

Page 12

Advertising
background image

4

2.3

INSTALLATION

Typical Remote Pump Installation

The hopper mix pump is completely installed on the

freezer. The remote mix pump is designed for mounting

in a walk-in cooler. Select a location that is close to the

soft serve freezer and a grounded 115 volt (220 volt if

50 hertz) receptacle. The mix pump should not be

located near heavy traffic or in a congested area. Refer

to Figure 2 and the following steps:

REMOTE MODELS INSTALLATION

A. Install the mix pump in an upright position on the

wall. Allow clearance for a mix can under pump.

Mount by bolting bracket to wall using 1/4 inch

(64cm) diameter lag bolts of sufficient length to hold

securely.

B. Connect 5/8 inch (1.60 cm) I.D. plastic food grade

tubing between pump cylinder (inlet) and mix

container.

C. Connect 1/2 inch (1.27 cm) plastic food grade tubing

between pump body mix transfer tube (outlet) and

refrigerated mix transfer line. Secure with No. 26

hose clamp or equivalent.

D. Connect 1/2 inch (1.27 cm) plastic food grade tubing

between safety relief fitting to a separate pail or shot

can.

NOTE

This line allows mix to escape if the system

pressure should exceed 30 P.S.I.

E. Plug mix pump into a 115 volt grounded receptacle.

(Customer must provide plug for 220 volt, 50 hertz

remote pump.)

WARNING

TO MINIMIZE SHOCK HAZARD, THE REMOTE

MIX PUMP MUST BE PLUGGED INT O A

PROPERLY GROUNDED ELECTRICAL

RECEPTACLE WITHOUT THE USE OF A

GROUND ADAPTER PLUG.

2.4

MIX PUMP CHECK OUT

The mix pump has been thoroughly cleaned and properly

lubricated at the factory. Before using, the mix pump

should be disassembled. This is necessary to remove

any foreign materials and to familiarize operators with

the correct assembly procedures.

A. The over-run adjustment is preset at the factory . If

an adjustment becomes necessary, refer to Section

4.1.

B. The pump pressure is preset at the factory. If an

adjustment becomes necessary, refer to Section 4.2.

C. On remote pumps, check for air leaks by placing

the suction line into three gallons of cold water. Place

the freezer switches in the OFF position. Close the

spigot and freezer air vents. Place mix pump switch

in the ON position and allow the system pressure to

build up and pump to shut OFF automatically. Leave

pump on for ten minutes. During this time do not

open spigot or freezer air vent s. If pump does not

automatically start again during this period, the

system is free of leaks. If the pump does start, there

is a leak in the system. Locate leak by applying a

liquid detergent or bubbles solution with a small

brush to all tubing connections and “O”-ring seals.

Correct as required.