To adjust the mix pump for a lower over-run, refer to

Figure 14, and follow the adjustment procedures below:

CAUTION

THE MIX PUMP SWITCH MUST BE IN THE OFF

POSITION WHEN SERVICING OR CLEANING

PUMP.

A. Remove two knobs and safety guard covering drive

mechanism.

CAUTION

THE DRIVE MECHANISM MUST BE

POSITIONED AT THE BOTTOM OF THE

STROKE.

B. The position of the stroke is adjusted by loosening

the jam nut (B) above the drive clevis (C), and then

turning the drive clevis down for a lower over-run.

The drive clevis and yoke stud (A) must be engaged

by a minimum of four full threads.

4.2

PRESSURE CONTROL SWITCH

The pressure control switch control the pressure at

which the mix pump cuts in or out. This switch can not

be adjusted.

NOTE

Pressure gauge manifold accessory kit (Part No.

1156527) is available to check pressures.

CAUTION

DISCONNECT ELECTRICAL SUPPLY TO MIX

PUMP BEFORE SERVICING.

A. Install the pressure gauge kit into the pressure

switch. Figure 15.

Figure 15. Pressure Gauge

B. Connect electrical input power to the mix pump.

C. The pressure check must be made with either water

or mix in the freezer cylinder.

D. Place the mix pump switch in the ON position and

check pressures.

4.3

PREVENTIVE MAINTENANCE

It is recommended that a preventive maintenance

schedule be followed to keep the mix pump clean and

operating properly. The following steps are suggested

as a preventive maintenance guide.

WARNING

NEVER ATTEMPT TO REPAIR OR PERFORM

MAINTENANCE ON MIX PUMP UNTIL ALL

MAIN ELECTRICAL POWER HAS BEEN

DISCONNECTED.

The United States Department of Agriculture and the

Food and Drug Administration require that lubricants

used on food processing equipment be certified for this

use. Use lubricants only in accordance with the

manufacturer’s instructions.