5

SECTION 3

OPERATION INSTRUCTIONS

3.1

SAFETY PRECAUTIONS

Do not attempt to operate the mix pump until the safety

precautions and operating instructions in the manual are

read completely and thoroughly understood.

Take notice of all warning labels on the mix pump. The

labels have been put there to help in maintaining a safe

working environment. The labels are designed to withstand

washing and cleaning. All labels must remain legible for

the life of the mix pump. Labels should be checked

periodically to be sure they have not been removed,

painted over, rubbed off, and can be recognized as

warning labels.

If replacement labels are needed, indicate the part

number, type of label, location of label, and quantity

required. Mail your name and address to:

STOELTING, LLC

ATTENTION: CPG Customer Service

P.O. Box 127

Kiel, Wisconsin 53042-0127

Labels will be furnished and mailed at no charge.

SAFE OPERATION IS NO ACCIDENT; Observe these

rules:

A. Know the mix pump- read and understand the Owner’s

Manual.

B. Wear proper clothing - avoid loose fitting garments,

and remove watches, rings or jewelry which could

cause a serious accident.

C. Maintain a clean work area – avoid tripping or slipping

by cleaning up the area and keeping it clean.

D. Stay alert at all times – know which switch, push

button or control you are about to use and what effect

it is going to have.

E. Turn all switches to OFF prior to making any

adjustments.

F. Do not attempt to repair or perform maintenance on

the mix pump until the main electrical power has been

disconnected.

G. Do not operate the mix pump if unusual or excessive

noise or vibration occurs.

3.2

PUMP MOTOR SWITCH

The PUMP MOTOR switch (see Fig. 3) is located on the

mix pump assembly. When the pump motor switch is

placed in the ON position, the mix pump motor will be

actuated to pump mix into the freezer cylinder. When the

set pressure is reached, the mix pump will shut off

automatically. When the pump motor switch is placed in

the OFF position. The mix pump will be inoperative.

The mix pump motor is equipped with an overload push

button reset switch (labeled “Drive Reset”) that will “kick-

out” when the motor is overloaded. Motor overloads can

be caused by several things including improper assembly

of the pump or worn parts causing binding, or electrical

probems. Pressing the reset button will return the motor

to normal operation if the overload condition is no longer

present. If the If the pump assembly seems to move freely

but the overload condition continues, contact a qualified

service person.

Figure 3. Pump Controls

Advertising