Konica Minolta IC-308 User Manual

Page 55

Advertising
background image

5-7

bizhub PRESS C1100/C1085

5

O

Measure a misalignment between the

marks of [1] to [4] printed on the

[back] side of the output chart and the

marks on the [front] side.

-

In this figure, the black mark

indicates

the front side and the blue mark

indicates

the back side.

-

Measure a misalignment between printing
positions in the horizontal direction (X axis)
and vertical direction (Y axis).

-

The measurement value can be entered in
units of up to 0.1 mm.

-

For example, as illustrated in this figure, if the

mark of [1] printed on the back side is

misaligned 0.5 mm rightward and 0.3 mm
downward compared with the mark printed
on the front side, adjust the printing position
0.5 mm in the X direction and 0.3 mm in the
Y direction.

-

Write down the measured values so that you
do not forget them.

P

Press [X] or [Y] at each point, then enter the measured value using either the keypad
on the screen, [,], or [+].

-

If the printing position is misaligned leftward or upward, enter the value with a negative sign (-). If the
printing position is misaligned rightward or downward, enter the value with a positive sign (+).

-

To reset a value, press [Clear].

-

To switch the positive sign (+) and negative sign (-), press [+/-].

[ 1 ]

back

x

y