background image

5-24

5.2

Image Quality Adjustment

Particular adjustment

If a particular adjustment is required, for example, before printing out an image with a higher level of quality or when
the expected chromogenic effect has not been obtained as expected, adjust the following items:

Reference

For details about the adjustment procedure, refer to the HTML User's Guide.

NOTICE

NOTICE

Precaution on using Color Density Control

To use [Each Paper Type Color Adj.] in "Color Density Control", carry out [Each Paper Type Color Adj.] before starting
this procedure, then configure a tray setting.
For details, refer to the HTML User's Guide.

Ad-
just-
ment
order

Menu item

Description

Tips

1

Gamma Automat-
ic Adj.

Adjusts the curve of the output density against the in-
put density.
This affects the brightness and contrast.
On the [MACHINE] screen, select [Adjustment] - [Exe-
cute Adjust Operation] - [Gamma Automatic Adj.] to
execute processing.

HTML User's Guide

2

Maximum Density
Adjustment

Changes the maximum density adjustment value
when the measurement density that was obtained af-
ter calibration does not match the reference adjust-
ment value.
[Administrator Setting] - [System Setting] - [Expert
Adjustment] - [Process Adjustment] - [Maximum Den-
sity Adjustment]

HTML User's Guide

3

Color Density
Control

Executes automatic calibration.
On the [MACHINE] screen, select [Adjustment] -
[Color Density Control] - [Basic Setting] or [Color Den-
sity Manual Control] to carry out the adjustment.

p. 5-14

4

Printer controller
calibration

Executes manual calibration. Use Fiery Command
WorkStation.

p. 5-19