3. Control Panel Keys and Indicators

2-9

Scann

er

Ch

ap

te

r 2

Film Type Key:

Rotates between Auto, Nega, and Posi each time the key is
pressed.

1) Auto: The scanner automatically determines between

the film type options of negative or positive for
print production.

2) Nega: Select when using negative film. Dark and light

values of the print will be reversed.

3) Posi:

Select when using positive film. Dark and light
values of the print will be consistent with the im-
age on film.

Exposure Adjustment
Keys:

Use this key to adjust the image density of the image to be
printed during the Auto or Manual Exposure mode. The
Darker key supports darker image density and the Lighter
key supports lighter image density.

Exposure Mode Key:

Press to select between the Auto or Manual Exposure
mode.

Exposure Display:

Indicates the current density level of the printed image.

Exposure Mode Indica-
tor:

Auto Exposure mode is indicated when the green Auto
light is on. The green Auto light turns off when the Scanner
is in the Manual Exposure mode.

Multi-Print Display:

Shows the number of prints set to be made. Also displays
corresponding codes in the event of a malfunction or paper
misfeed. The blinking number in this display indicates the
Scanner in operation.

Add Toner Indicator:

Blinks when the Imaging Cartridge or Toner Cartridge of
the Printer is running out of toner and lights up when the
cartridge has completely run out of toner.
* PR mode only.