12.7 Drain pump

Regularly examine the drain
pump and make sure that it is
clean.

Clean the pump if:
• The appliance does not drain the wa-

ter.

• The drum cannot turn.
• The appliance makes an unusual noise

because of the blockage of the drain
pump.

• The display shows an alarm code be-

cause of the problem with water drain.

WARNING!

1.

Disconnect the mains plug
from the mains socket.

2.

Do not remove the filter
while the appliance oper-
ates. Do not clean the drain
pump if the water in the ap-
pliance is hot. The water
must be cold before you
clean the drain pump.

To clean the drain pump:

1.

Open the drain pump door.

2.

Pull the flap out to remove it.

3.

Put a container below the recess of
the drain pump to collect the water
that flows out.

4.

Press the two levers and pull for-
ward the drainage duct to let the
water flow out.

1

2

5.

When the container is full of water,
put the drainage duct back again
and empty the container. Do steps 4
and 5 again and again until no more
water flows out from the drain
pump.

6.

Pull back the drainage duct and turn
the filter to remove it.

ENGLISH