Installation instructions continued, Table 2 — distance to finished floor, Step 6: installing the valve assembly – Bradley Smoker WF2708 User Manual

Page 15: Valve assembly

Advertising
background image

Classic Circular 36"/54" Washfountain with Foot Control

Installation Instructions

WF2605, WF2608 Terrazzo — WF2705, WF2708 Stainless Steel

Bradley Corporation • 215-603 Rev. M; EN 06-915B

15

4/6/2007

Installation Instructions continued . . .

Step 6: Installing the Valve Assembly

NOTE: Flush supply lines before making connections.

1. Connect the stop-strainer-check valves, mixing valve, volume control valve, and foot valve as

shown in Figure 10.

2. For overhead supply lines, install 1/2"nominal copper supply tubing by passing the lines through

the holes in the dispenser cover and then down through the support tube.

3. Install the valving assembly using suitable fittings to the supplies as shown in Figure 10 at the

approximate height indicated in Table 2.

4. Slide the tailpiece nut over the tailpiece and connect the tailpiece to the supply pipe (or to the

nipple/coupling for B or H drain).

Operating Lever

Coupling

(169-174)

Nut

(110-005)

Tailpiece

(129-009)

Nipple

STD: 2" Long (113-852)
JUV: Close (113-006AL)

Tailpiece Washer

(124-001AF)

Used on "B"
and "H" models only

To Supply Pipe

Foot Valve

(S07-066)

OPTIONAL Vernatherm™

Thermostatic

Mixing Valve

(S01-525)

(Units are supplied with

Manual Mixing Valve as

standard equipment)

Stop-Strainer-Check

Valve

(S60-003)

Washer

(124-001AF)

Nut

(110-005)

Tailpiece

(129-007)

Manual Mixing

Valve

(S01-038)

Valve Assembly

Distance (dimension)

finished floor - see

Table 2

Figure 10

Model Number

Type A

Type B

Type H

Type O

Standard Height

9" (229mm)

6-3/16" (157mm)

6-3/16" (157mm)

9" (229mm)

Juvenile Height

5-1/4" (133mm)

3-7/16" (87mm)

3-7/16" (87mm)

5-1/4" (133mm)

Table 2 — Distance to Finished Floor

Advertising