V - 41
WSW28
(Function setting 6)
Selector
No.
Function
Setting and Specifications
1
|
3
Transmission level of DTMF high-
band frequency signal
No. 1 2 3
0 0 0
:
0 dB
0 0 1
:
+1 dB
0 1 0
:
+2 dB
0 1 1
:
+3 dB
1 0 0
:
0 dB
1 0 1
:
-1 dB
1 1 0
:
-2 dB
1 1 1
:
-3 dB
4
|
6
Transmission level of DTMF
low-band frequency signal
No. 4 5 6
0 0 0
:
0 dB
0 0 1
:
+1 dB
0 1 0
:
+2 dB
0 1 1
:
+3 dB
1 0 0
:
0 dB
1 0 1
:
-1 dB
1 1 0
:
-2 dB
1 1 1
:
-3 dB
7
8
Not used.
l
Selectors 1 through 6:
Transmission level of DTMF high-/low-band frequency signal
These selectors are intended for the manufacturer who tests the equipment for the Standard.
Never access them.