B&B Electronics Command Response Protocol HVD100A3 User Manual

Page 15

Advertising
background image

HDV100A3 Command & Response Manual-1306cr

11

B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350

PH (815) 433-5100 -- FAX (815) 433-5104


Master Reset Command

The master reset command allows the HDV100A3 to be reset from the PC.
Sending this command resets the HDV100A3 to the default start-up state.
You will lose all setting sent in the smart mode.


Byte
Number

Byte
Value

Function

1

01

Start of frame

2

04

Number of control bytes

3

08

ID byte 08 = internal command

4

08

Function code 08= master reset

5 01

Check

byte

6 02

Check

byte

7

00

Number data bytes

8 18

Checksum


Note: after sending a master reset the baud rate is 115,2k (default).



Vendor Information

To receive the vendor information from the HDV100A3 send hex (01, 01,
05, 00, 07) to the device. It will respond as follows:

Hex (01, 0B, 85, MM, DD, MA, M1, M2, MO, 00, VV, VV, 00, DB, CS)

0B = Number of control bytes

85 = Compatibility with other models

MM = Month firmware was created

DD = Day firmware was created

MA = Major firmware revision number

M1 = MSB of minor firmware revision

M2 = LSB of firmware revision

MO = Model

VV = Customer code 1

VV = Customer code 2

DB = Number of data bytes

CS

=

Checksum