Byte
number

Byte value
(hex)

Byte Function

1

01

Start of frame

2

02

The number of control bytes

3

01

ID byte 01= J1708

4 10

Function

code

10 hex stop receive

5

00

Number of data bytes (00 place holder)

6

14

Checksum (bytes 1 through 5 added
together)

After sending this command to the device, the device will respond

with a confirmation message and data will cease. Note that there is the
possibility of an incomplete message being sent to the PC after sending this
command. Use the check-sum to verify all messages.

To restart reception, send the (01, 02, 01, 11, 00, 15) command to

the HDV.