20

HDV100A3 Command & Response Manual-1306cr

B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350

PH (815) 433-5100 -- FAX (815) 433-5104

wise to set the receiver off when not in use. Sending the Start Receive clears
the mask. This renders the filter function useless.

Start Receive on J1939 Bus
Byte
Number

Byte
Value

Function

1

01

Start of frame

2 02

Control

bytes

3

02

ID byte 02 = J1939 message

4

01

Function code 01 start reception

5 00

Data

bytes

6 06

Checksum


Stop Receive on J1939 Bus

Byte
Number

Byte
Value

Function

1

01

Start of frame

2 02

Control

bytes

3

02

ID byte 02 = J1939 message

4

00

Function code 00 stop reception

5 00

Data

bytes

6 05

Checksum