TABLE 5—ELECTRICAL DATA—601A

UNIT 601A

SIZE

V-PH-HZ

VOLTAGE

RANGE

COMPRESSOR

OFM

FLA

IFM

FLA

ELECTRIC HEAT

SINGLE POINT POWER SUPPLY

MIN

MAX

RLA

LRA

Nominal

kW*

FLA

MCA

FUSE OR
CKT BKR

MOCP

030

208/230–3–60

187

253

9.9

78

0.9

2.0

-/-

3.8/5.0

7.5/10.0

11.3/15.0

-/-

10.4/12 .0

20.8/24.1
31.3/36.1

15.3/15.3
28.3/30.3
41.3/45.3
54.4/60.4

20/20
30/35
45/50

60/-

-
-
-

-/70

036

208/230–3–60

187

253

9.9

78

1.5

4.1

-/-

3.8/5.0

7.5/10.0

11.3/15.0

-/-

10.4/12.0
31.3/36.1
36.1/41.7

18.0/18.0
31.0/33.0
44.0/48.0
57.1/63.1

25/25
35/35
45/50

60/-

-
-
-

-/70

460–3–60

414

506

5.5

40

0.8

1.9

-/-

5

10
15

-/-

6.0

12.0
18.0

9.6

17.1
24.6
32.1

15
20
25
35

-
-
-
-

042

208/230–3–60

187

253

12.4

90

0.9

3.8

-/-

3.8/5.0

7.5/10.0

11.3/15.0
15.0/19.9

-/-

10.4/12.0
20.8/24.1
31.3/36.1
41.6/48.0

20.2/20.2
33.2/35.2
46.3/50.3
59.3/65.3
72.2/80.2

25/25
40/40
50/60

60/-

-

-
-
-

-/70

80/90

460–3–60

414

506

6.7

45

0.8

1.8

-/-

5

10
15

20.0

-/-

6.0

12.0
18.0
24.1

11.0
18.5
26.0
33.5
41.0

15
20
30
35
45

-
-
-
-
-

048

208/230–3–60

187

253

14.1

105

1.5

3.5

-/-

3.8/5.0

7.5/10.0

11.3/15.0
15.0/20.0

-/-

10.4/12.0
20.8/24.1
31.3/36.1
41.6/48.0

22.6/22.6
35.7/37.7
48.7/52.7
61.7/67.7
74.6/82.6

30/30
40/40
50/60

-
-

-
-
-

70/70
80/90

460–3–60

414

506

7.1

53

0.8

1.8

-/-

5

10
15
20

-

6.0

12.0
18.0
24.1

11.5
19.0
26.5
34.0
41.5

15
20
30
35
45

-
-
-
-
-

060

208/230–3–60

187

253

19.4

125

1.5

6.2

-/-

3.8/5.0

7.5/10.0

11.3/15.0
15.0/19.9

-/-

10.4/12.0
20.8/24.1
31.3/36.1
41.6/48.0

32.0/32.0
45.0/47.0
58.0/62.1
71.1/77.1
83.9/91.9

40/40
50/50

-
-
-

-
-

60/70
80/80

90/100

460–3–60

414

506

8.0

63

0.8

3.2

-/-

5

10
15
20

-

6.0

12.0
18.0
24.1

14.0
21.5
29.0
36.6
44.1

20
25
30
40
45

-
-
-
-
-

—12—